Why CO₂ Monitoring Matters in Hospitality

CO₂ Safety in Pubs, Bars, Restaurants and Beverage Environments 

Great hospitality is all about the right atmosphere, great drinks, confident staff and customers just enjoying the moment, without having to think about what's happening behind the scenes. 

But there is another atmosphere hospitality businesses need to think about and that’s the air their people are working in. 

Carbon dioxide (CO₂) is an essential part of the industry. It's produced naturally during brewing and winemaking and is widely used in beverage dispense systems, packaging, purging and storage. 

The challenge, however, is that CO₂ is colourless and odourless. You can't see or smell it, and without the appropriate monitoring, you won’t be aware that levels are rising. 

That's why understanding where CO₂ can occur, the risks it presents and how to monitor it is an important part of creating a safer hospitality environment. 

Where Is CO₂ Found in Hospitality? 

CO₂ can be present in more areas of a hospitality business than you might initially expect. 

It is commonly associated with: 

  • Beer and soft drink dispense systems
  • Brewing and fermentation 
  • Cellars 
  • Cold rooms
  • Gas cylinder storage
  • Packaging and production 
  • Purging processes
  • Beverage storage areas 

In brewing and winemaking, CO₂ is produced naturally during fermentation. Elsewhere, it may be supplied from cylinders or bulk storage and distributed through pipework to wherever it is required. 

This means the potential source of CO₂ isn't necessarily limited to one location.

Why Can CO₂ Be Dangerous? 

CO₂ presents a particular challenge because you cannot rely on your senses to identify it. 

It is: 

  • Colourless - you can't see it 
  • Odourless - you can't smell it 
  • Denser than air - meaning it can accumulate in low-lying areas 

Cellars, cold rooms and other enclosed or poorly ventilated spaces can therefore be particularly important areas to consider when assessing CO₂ risk. 

CO₂ may also migrate away from the original source of a leak, meaning elevated concentrations can potentially occur somewhere staff don't immediately associate with the gas. 

As concentrations increase, exposure can cause symptoms including headaches, dizziness, confusion and shortness of breath. At higher concentrations, exposure can lead to loss of consciousness and can be fatal.

Where Can CO₂ Leaks Occur? 

CO₂ is safely used throughout the hospitality industry every day, but equipment faults and leaks can happen. 

Potential problems can occur around: 

  • Cylinders and storage systems 
  • Pipework and connections 
  • Beverage dispense equipment
  • Cylinder changeovers 
  • Maintenance activities
  • Damaged or incorrectly connected equipment 

Even a relatively small leak can become significant if CO₂ is continuously released into an enclosed or poorly ventilated area. 

And because there may be no obvious indication that a leak has occurred, staff shouldn't have to rely on seeing, smelling or otherwise recognising that something is wrong. 

This is where gas monitoring becomes particularly important. 

Why Is Continuous CO₂ Monitoring Important? 

A fixed CO₂ monitor continuously measures the atmosphere, providing an early warning when gas concentrations reach configured alarm levels. 

Instead of relying on someone noticing a potential problem, the monitoring system is working in the background throughout normal operations. 

If elevated levels are detected, an alarm can warn staff before they enter or remain in an affected area, giving them the opportunity to follow the appropriate site safety procedures. 

This can be particularly important in locations that staff enter intermittently, such as cellars and cold rooms. Conditions may have changed since someone was last in the space, even though everything appears completely normal from outside. 

Continuous monitoring provides visibility of a risk that would otherwise be invisible. 

Fixed Gas Monitoring with the Analox Ax60+ 

The Analox Ax60+ is a scalable fixed gas monitoring system designed to provide continuous monitoring across hospitality, food and beverage environments. 

Depending on the sensor configuration, the Ax60+ can monitor: 

  • Carbon dioxide (CO₂) 
  • Oxygen (O₂) enrichment or depletion 
  • Carbon monoxide (CO) 

When configured alarm levels are reached, the system provides clear audible and visual warnings, helping staff recognise when conditions may be unsafe and respond appropriately. 

Monitoring Multiple Areas 

Hospitality businesses can have several potential areas of risk within the same venue. 

For example, CO₂ cylinders might be stored in one location, dispense equipment in another, with a separate cellar or cold room elsewhere in the building. 

The Ax60+ can connect up to four sensors to one central unit, allowing multiple critical areas to be monitored as part of the same system. 

This provides flexibility for businesses ranging from smaller hospitality venues through to larger restaurants, breweries, hotels, entertainment venues and stadiums. 

Connecting Monitoring with Ventilation 

Gas monitoring doesn't have to operate in isolation. 

The Ax60+ can interface with external systems, including ventilation. Where appropriate, ventilation can therefore be activated automatically when configured gas levels are detected. 

This can help form part of a wider approach to managing gas safety within the venue, combining detection, warning and response.

Personal CO₂ Monitoring 

Fixed monitoring provides continuous protection for a defined area, but there are situations where personal gas detection can provide an additional layer of awareness. 

This can be particularly useful for: 

  • Maintenance engineers 
  • Gas delivery personnel 
  • Contractors 
  • Staff changing cylinders 
  • People working across multiple locations 

Portable monitors such as the Aspida and CO₂BUDDY move with the individual and provide an immediate warning if they encounter elevated CO₂ levels. 

Used alongside fixed monitoring, personal detectors can form part of a broader approach to protecting people working around CO₂. 

Protecting More Than the Cellar 

It's easy to associate CO₂ safety with a particular piece of equipment or a cellar full of cylinders. 

The reality is that gas doesn't necessarily remain where you expect it to. 

Understanding where CO₂ is used, where it could accumulate and how people interact with those areas is an important part of assessing the risk. 

Effective monitoring provides the information human senses can't. It gives staff an early warning, helps businesses respond quickly and supports safer working practices throughout the hospitality environment. 

Ultimately, gas safety is about protecting the people working behind the scenes, the customers enjoying the experience and the business and reputation built around them. 

Great hospitality depends on creating the right atmosphere. Monitoring helps make sure the atmosphere behind the scenes is the right one too. 

Need Help Understanding Your CO₂ Monitoring Requirements? 

Every hospitality environment is different. The location of gas supplies, dispense equipment, ventilation and occupied areas can all affect where monitoring should be considered. 

Talk to Analox about your application and the most appropriate gas monitoring solution for your environment. 

To learn more about our CO₂ detection systems, explore below: