ACG+

Monitor for Compressed Breathing Air

Say goodbye to fiddly tube tests and expensive lab analysis and say hello to a reliable, accurate monitor which can help you meet EN12021, DEF-STAN 68-284, CGA, CSA and OSHA compliance.

In the highly precise world of compressed breathing air, true professionals demand proven results, consistent reliability along with turnkey installation and maintenance. The Analox team recognises this and has built the ACG+ to answer these challenges.

Key Features

  • Provides continuous monitoring 24/7
  • Low maintenance and is easy to install and maintain
  • Provides 90 days of datalogging which you can easily retrieve via a USB connection
  • Cost effective alternative to colorimetric tube testing
  • Supplied as either a fixed or portable version depending upon your needs
  • Can be used on any breathing air compressor
  • Digital display

Information

Datasheets & Manuals

Technical Specifications

ACG+ Unit

FeatureSpecification
Power24V DC
Optional battery powerNiMH or Li-ION
Optional mains adaptorUniversal input 95 to 250 V AC, 50/60 Hz
IP RatingIP45
Response TimeT90 <120 seconds T90 <15 minutes H2O sensor
TemperatureOperating: −5 °C to 50 °C / 23°F to 122°F Storage: −10 °C to 60°C / 14°F to 140°F
Flow rate0.5L per minute (max)
Inlet Pressure5-10 Bar Gauge (Optional regulator can be purchased)
Humidity0-99% RH (Non Condensing)
Outputs1 x normally open relay contacts 1 x normally closed relay contacts 3 x 24 V DC switched output

ACG+ Sensors

FeatureO2 SensorCO2 SensorCO SensorVOC SensorWater Vapor Sensor
Range0 to 50%0 to 1000 ppm0 to 20 ppm0 to 100 ppm0 to 100 mg/m3
Accuracy±(0.035% O2 + 1% of reading + ±(0.035% O2 + 1% of reading + 0.15% of reading/°C)±(25 ppm CO2 + 1% of reading + 1 ppm CO2/°C)±(1 ppm CO + 5% of reading + 0.1 ppm CO/°C)±(1 ppm VOC + 5% of reading + 0.25% of reading/°C)±(0.15 mg/m3 H2O + 20% of reading)
TechnologyAnalox MEC intelligent electrochemical oxygen sensorAnalox 5S3 intelligent NDIR sensorAnalox MEC intelligent electrochemical sensorAnalox MEC intelligent PID sensorWater vapour sensor using capacitive technology

Additional Information

A Proven Solution

Analox understands the unique demands of military vessels operating in diverse locations and situations. For more than 30 years, Analox has been working with military decision-makers representing more than two dozen nations. Analox products are currently protecting sailors aboard vessels representing the Royal Navy, Royal Norwegian Navy, Royal Netherlands Navy and United States Navy.

The Analox Team of engineers and product development specialists created the ACG+ for work in multiple environments, addressing a variety of situations and applications.
In early 2021, the International Association of Oil and Gas Producers (IAGP) released updated standards for diving operations. The Analox ACG+ is a proven tool for commercial diving professionals maintaining these standards on a daily basis.

A Reliable Tool

The ACG+ offers continuous monitoring of up to five different gas variables (oxygen, carbon monoxide, carbon dioxide, volatile organic compounds and water vapor) and simultaneously displays results for testing and calibration purposes. This eliminates potential delays and downtimes while test results are sent out for analysis.

The ACG+ has also made cumbersome colorimetric tubes obsolete by drastically reducing the potential for human error in gas analysis. The continuous monitoring also has virtually eliminated the need for time-consuming spot checks.

The ACG+ simultaneously scans for O₂, CO₂, CO, VOCs and water vapor, making it one of the most versatile tools any vessel can utilize. The automatic data log provides additional peace of mind for decision makers.

A Cost Effective Solution

You can’t put a price on safety, reliability and peace of mind. The Analox development team created the ACG+ to combine multiple tasks simultaneously, reducing the need for multiple analyser units, costly test tubes, and often, extended times in port for repairs.

The ACG+ is available in either a fixed location model or convenient portable units. This adaptability provides designers, procurement officers and equipment specialists some options in closed quarter situations.

Easy to Install and Maintain

The Analox team understands the complexities and challenges that accompany equipment installation. That is why our 24/7 technical support department was created. Instant solutions and technical support is always just a call or email away.

While each ACG+ unit can monitor up to five gasses simultaneously, each analytical system operating in the ACG+ is independent of the others. This means sensors can be replaced individually without needlessly causing downtime.

An Easy Choice

The Analox ACG+ has been proven effective in military situations around the world. The unit’s continuous and specific monitoring capabilities make it an easy choice for key decision-makers.

Applications
  • Diving
  • Emergency Services
  • Manufacturing
  • Paint Spraying
  • Ships
  • Medical

Obsolete Product Manuals

Frequently Asked Questions

Can the ACG be used to test the quality of breathing air used to protect personnel from hazards posed by a hazardous substance covered by the COSHH regulations?

In part yes, the ACG can measure the quality of breathing air to the standards required for the gasses it measures, O₂, CO₂, CO, VOC’s and H₂O. The required standards listed in the Approved Code of Practice (ACOP 9) are the same as BS EN 12021. Where the risk assessment for a process highlights a gas that is not measured by the ACG. I.e. a hazardous substance used, produces a harmful gas in quantities greater than safe exposure limits, such that it is a danger. Depending upon the gas in question it may be possible to test for the gas using the ACG’s sample support function with a colorimetric tube specific to the gas. If this is not possible then the ACG would not be suitable as the only test method employed under the COSHH regulations.

How often would you suggest I take an oil mist sample at the ACG’s sample support port?

The frequency of routine sample testing depends upon the level of usage of the compressor, how close to the design limits it is used and the scale of impact that contaminated gas would have on the compressed air system to which it is attached. As a minimum we would recommend performing an oil mist sample test at least once every three months, to coincide with the calibration checks of the other sensors in the ACG. Another good practice is to perform an oil mist sample test when the water, CO or VOC sensors alarm as they may be indicating a compressor problem, particularly if the source of the alarming contaminant is not obvious.

Can I use an ACG+ to monitor compressors using synthetic oil?

Because many of the mechanisms that generate oil vapor/mist also generate other contaminants such as VOC’s, CO and water vapor, the ACG+ is suitable for monitoring compressors using both synthetic oil and mineral oil. The ACG+ monitors for these contaminants which, when detected, can give an indication that problems may be present with the compressor (resulting in the generation of oil mist). These indications can be used as a prompt to perform an oil mist test using the sample support feature.

Can I use the sample support port for any type of color metric tube?

Yes, this feature adds flexibility to the user to use a variety of tubes for any type of gas.

How do I replace the CO sensor on the ACG+?

The ACG+ CO sensor should be replaced approximately every 2 years (or as required). This procedure is detailed in the ACG+ user manual.

We also have created an instruction video for this procedure, we hope you find this useful:

How do I replace the dew point sensor on the ACG+?

The ACG+ dewpoint (water vapor) sensor should be factory calibrated/ exchanged every 2 years. This procedure is detailed in the ACG+ user manual.

 

How do I replace the O₂ sensor on my ACG+?

The ACG+ O₂ (oxygen) sensor should be replaced approximately every 2 years (or as required). This procedure is detailed in the ACG+ user manual.

How to install the ACG+ PC Tool for the ACG+