MEC

Mini Electrochemical Sensor

Analox’s MEC family is the world’s most extensive range of toxic OEM gas sensors providing a digital output.

The Analox MEC (Mini Electrochemical) is a small, robust sensor module available in a range of gas variants. All variants are housed in an IP65 enclosure and conform to the same physical dimensions, power requirements and communication protocol.

Key Features

  • Sensor can easily be replaced
  • Digital output for OEM integration
  • IP65 enclosure - totally dust tight and protected against low-pressure water jets
  • Integral pressure sensor - providing compensation for the effects of atmospheric pressure
  • Digital communication (via RS485) - sensor can be mounted remotely from monitoring equipment
  • Available in a wide range of gas variants
  • Long life sensor - lasts up to 50,000 hours
  • Easily integrated into larger gas management systems

Information

Datasheets & Manuals

Technical Specifications

MEC O2 Sensor

FeatureSpecification
Range0 to 100% (atmospheric pressure), 0 to 3000 mbar (hyperbaric)
Temperature range−5 to 55 °C (23 to 131 °F)
Accuracy (over ±10 °C)±(0.035% O2 + 1% of reading + temperature coefficient), temperature coefficient = 0.4% of reading/°C or 0.22% of reading/ °F
Detection modeelectrochemical
Sensor Life2 years for the electrochemical cell in atmospheric air
Supply voltage5.0 V DC (±0.5 V)

MEC CO Sensor

FeatureSpecification
Range0 to 20 ppm
Temperature range−5 to 55 °C (23 to 131 °F)
Accuracy (over ±10 °C)±(1 ppm CO + 5% of reading + temperature coefficient), temperature coefficient = 0.1 ppm CO/°C + 0.5% of reading/°C or 0.056ppm CO/°F + 0.278% of reading/°F
Detection modeelectrochemical
Sensor Life2 years in operation
Supply voltage5.0 V DC (±0.5 V)

MEC He Sensor

FeatureSpecification
Range0 to 100%
Temperature range−5 to 55 °C (23 to 131 °F)
Accuracy (over ±10 °C)±(2% FS + temperature coefficient), temperature coefficient = 0.05% FS/°C or 0.028% FS/°F
Detection modepellistor
Sensor Lifeup to 5 years
Supply voltage5.0 V DC (±0.1 V)

VOC Sensor

FeatureSpecification
Range0 to 100 ppm
Temperature range−5 to 55 °C (23 to 131 °F)
Accuracy (over ±10 °C)±(1 ppm VOC + 5% of reading + 0.25% of reading °C)
Detection modeAnalox MEC intelligent PID sensor
Sensor Life5,000 hours (~6 months), Cell - 50,000 hours (~5 years)
Supply voltage5.0 V DC (±0.5 V)

Additional Information

Gas monitoring with the MEC

Oxygen Sensor

The Analox MEC Oxygen (O₂) Sensor has been inspired by the proven 9212 range of electrochemical oxygen (O₂) sensors.
The principle of electrochemical galvanic action is used by the cells to operate. This produces an electrical current proportional to the absorption of oxygen through a Teflon membrane.

The partial pressure of oxygen present is proportional to the absorption rate.
The sensor output is virtually immune to cross-interference, as neither the membrane or partial pressure of oxygen (O₂) are affected by the majority of most other gases.

The 9212 series sensor within the Analox MEC Oxygen (O₂) Sensor and the Analox MEC Oxygen (O₂) Sensor itself are both field replaceable, which helps give them a long life expectancy and make them very cost-effective for the monitoring of oxygen.

Carbon monoxide Sensor

Electrochemical cells are utilised by the Analox MEC CO sensors.

For monitoring carbon monoxide, the Analox MEC CO sensors are extremely cost-effective, with field replaceable cells that have a long life expectancy.

Integration into larger gas management systems has been made easy, with a digital serial communications interface.

Helium Sensor

Breathing in pure helium (He) can cause death by asphyxiation in just minutes. Inhaling helium (He) from a pressurized tank can also cause a gas or air embolism, which is a bubble that becomes trapped in a blood vessel, blocking it. The blood vessels can rupture and haemorrhage.

The Analox ‘MEC He’ is ideal for integration into a breathing air compressor or system. Our sensors are highly accurate, compact and have a long life expectancy.

VOC Sensor

VOCs (volatile organic compounds) are any organic compounds having an initial boiling point less than or equal to 250°C, measured at a standard atmospheric pressure of 101.3kPa, and can cause damage to visual or audible senses. These include both man-made and naturally occurring chemical compounds.

Examples of common, everyday VOCs are gasoline fumes, paint solvents, air fresheners, construction chemicals such as carpet adhesives, dry cleaning and the gaseous portion of cigarette smoke. Along with particulates, VOCs are believed to be the major contributors to poor indoor (and outdoor) air quality. Most are thought to be carcinogenic in high concentrations and through long-term exposure.

A solution for all

Analox realizes that not all customers require a complete monitoring solution and prefer to integrate sensors into their own system, our range of sensors have been designed for this.

The MEC sensor range is ideal for this requirement if digital inputs are required. It is small enough to be integrated almost anywhere. Each housing has a gas port and using a simple flow adapter they can easily be installed in series in the gas path. An integral pressure sensor provides compensation for the effects
of atmospheric pressure where appropriate. The Analox MEC allows for easy replacement of sensor cells.

We also use MEC digital sensors in our own products, including the ACG+.

Note: If you wish to monitor sub-ppm levels of gas, the TEC range is also available.

Applications

MEC for OEM integration

  • Armoured vehicles
  • Original equipment manufacturer (OEM)
  • Laboratories
  • Food (MAP)
  • Green sector
  • Service
  • Emergency services
  • Manufacturing

Obsolete Product Manuals